THIF-127?????????VPI??
????????????????????
??? ?????????
THIF-127?????????????????????????????????????????棬????Ч??????????港?????????????????????г??????????Σ????Χ???????????????????????????????????????????????????????THIF-127???????????????????????????????????????????????????????????????????????????????Χ?У???????????????á??仺???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????й???????????
?????????VPI???????????????????????????ˉ????????????????????????????????????????????????????е??????????????е???????е??????????????????????????????????е??????????????????????????????????????????????????????????????????????????????????????????л??????????????????????????????????????
???????????????
??? ??? ??? ???
??? ???????? ?????????%?? 7%
?????%??≥ 98 ?????g/L?? 3.8
????棩 198-200 ???????棩 400
??????g/cm3?? 0.3 ???????Pa?? 12.4×10-3
PH??1%???????? 7-8 LD50(mg/lg) ≥ 500
????????????? ???≤ 0.4 ??????????????? ?????%??≤ 8
???? ?÷???????????
1?? THIF-127??????????????????????????????С?????????????????????£?????????50~100g/m3??
2?? THIF-127???????????÷??????????????
3?? THIF-127????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????档
4?? ?????????????????????????????????????????????
5?? ??????????????????????????????????????????????????????????????????
??? ?????????
?????????VPI????????????????????????????????????????????????18????????????????????????????????????????????λ????β??????????????????????????????
THIF-127 Vapor Phase Corrosion Inhibitors (VPI)
1.properties and uses
THIF-127 VPI is a corrosion inhibitor to a certain space within reach through the gasification of volatile metal surface to prevent the corrosion of metal surfaces corrosion chemicals, which replaces the current market-toxic, endangering the surrounding environment and the use of Health Gas inhibitor, is the base of nitrite-free environment-friendly high-tech products. THIF-127 vapor corrosion inhibitor performance, at room temperature vapor pressure are appropriate and adequate performance of proliferation, in order to ensure the protection of the metal corrosion inhibitor in the atmosphere, to play a role in anti-corrosion protection. Inhibition of its excellent performance, stability, good water-soluble, and paper, plastic, especially compatibility. Can be used directly, can also be used for a variety of vapor phase inhibitor VCI products such as water, VCI paper, VCI plastic film preparation, is an ideal long-term anti-corrosion material sealed, with a wide range of applications Prospects.
The product can be used in ships, buildings, bridges, boilers, generators, and other metal objects sealed cavity of the inner cavity for non-corrosion coating to protect, can also be used for military firearms, aviation, electronics, machinery, medical equipment and its parts and products Iron and steel parts and sheet metal products such as storage and transportation in the process of corrosion protection. Use it for corrosion protection of fabricated metal products, in use, not to oil, not only convenient but also to save oil resources and to avoid large-scale use of dissolved organic system when the oil seal to vehicle emissions, pollution On the environment.
2. the main technical performance
Indicators Project project targets
The appearance of a white crystalline powder volatile reduction (%) 7%
Purity (%) ≥ 98 Solubility (g / L) 3.8
Melting Point (??) 198-200 stability (??) 400
Bulk density (g/cm3) 0.3 vapor pressure (Pa) 12.4 × 10-3
PH (1% aqueous solution) 7-8 LD50 (mg / lg) ≥ 500
Rabbit skin irritation test score ≤ 0.4 sensitized guinea pig skin test allergens (%) ≤ 8
3. to use methods and attention to the points
a. THIF-127 vapor corrosion inhibitors may be the amount of protected material to calculate the size of the volume. In the fully sealed conditions, the amount is generally 50 ~ 100g/m3.
b. THIF-127 corrosion inhibitor gas distribution arrangement, according to design requirements.
c. THIF-127 vapor corrosion inhibitors placed in steel component cavity after the
volatile corrosion inhibitor continued until the gas saturation, its rust-proof steel depends on the length of the sealed components. In order to avoid unwarranted loss of corrosion inhibitor, is expected to affect the realization of the rust-proof, a good place vapor corrosion inhibitors of steel structures should be sealed in a timely manner.
d. Vapor corrosion inhibitors place, it is necessary to prevent contact with open flame, but also to prevent rain water was wet.
e. Vapor corrosion inhibitors place, they should wear gloves to prevent the metal surface and leave
traces Khan, the protection of metal on the surface of dry cleaning.
4. packaging and storage
This product can be requested by users of bulk and bagged two forms of packaging, bulk products for the Fiber drum (me), packing 18 kg. Bag fitted to the user based on the weight per bag in the form of packaging requirements, processing into a cylindrical or rectangular bag packaging, bag and then placed in storage within Fiber drum.