佳能绘图仪W8400及W6400报E02813和E02814的错误维修_大幅面打印机_新浪博客

佳能绘图仪W8400及W6400报E02813和E02814的错误维修

 

 

佳能绘图仪W系列(如W8400和W6400等)经常会出现如下的报错代码:

    E02813/ E02814 : Head management sensor error(打印头管理传感器错误

 

<Cause>(原因

    The head management sensor has detected an ink discharge error.(传感器无法检测到墨水
    A sensor sensitivity error was detected during position adjustment of the head management sensor.(传感器错误)


<Probable problem locations>(故障发生的可能位置
    Printhead, head management sensor, engine controller and system controller  

  打印头、打印头管理传感器、引擎控制板、系统控制板


<Remedy>(维修方法
    1. Replace the printhead.(更换打印头
    2. Visual check
       Remove any foreign objects adhering to the head management sensor.(检查打印头管理传感器附近有没有异物
    3. Replace the head management sensor.(更换打印头管理传器
    4. Cable connection check
       Replace the cable between the head management sensor and engine controller if the connection is not functioning normally.(检查打印头和主控制板之间的线缆
    5. Replace the engine controller.(更换引擎控制板
    6. Replace the system controller.(更换系统控制板

 

 