Type | Range | Linearity error (% F.S.) | L | X (nom) | Total weight | Armature weight | TF | Sensitivity (nom) | ||||||||||||||||||||
Inward over-travel | ||||||||||||||||||||||||||||
ACT500 | ±12.5mm | <±0.5/±0.25/±0.1 | 127mm | 43mm | 170g | 17g | 15mm | 16mm | 0.7V/V | |||||||||||||||||||
ACT1000 | ±25mm | <±0.5/±0.25/±0.1 | 155mm | 68mm | 227g | 23g | 15mm | 22mm | 0.9V/V | |||||||||||||||||||
ACT2000 | ±50mm | <±0.5/±0.25/±0.1 | 270mm | 81mm | 320g | 37g | 15mm | 16mm | 1.5V/V | |||||||||||||||||||
ACT3000 | ±75mm | <±0.5/±0.25/±0.1 | 380mm | 120mm | 454g | 55g | 15mm | 29mm | 1.5V/V | |||||||||||||||||||
ACT4000 | ±100mm | <±0.5/±0.25/±0.1 | 427mm | 132mm | 568g | 71g | 15mm | 16mm | 3.2V/V | |||||||||||||||||||
ACT6000 | ±150mm | <±0.5/±0.25 | 617mm | 183mm | 824g | 100g | 15mm | 16mm | 2.4V/V | |||||||||||||||||||
ACT8000 | ±200mm | <±0.5/±0.25 | 808mm | 259mm | 1.2kg | 140g | 29mm | 27mm | 1.5V/V |
Captive guided version. | ||||||||||||||||||||||||
Our captive guided displacement transducer has bearings to guide the armature inside the measurement sensor. Captive LVDTs are for position measurement applications where guidance may be poor and end bearings may be required. | ||||||||||||||||||||||||
|
||||||||||||||||||||||||
Type | Range | Linearity error (% F.S.) | L | X (nom) | D3 | Total weight | TF | Sensitivity (nom) | ||||||||||||||||
Inward over-travel | Outward over-travel | |||||||||||||||||||||||
ACT500C | ±12.5mm | <±0.5/±0.25/±0.1 | 152mm | 38mm | 4.75mm | 284g | 15mm | 10mm | 12mm | 0.7V/V | ||||||||||||||
ACT1000C | ±25mm | <±0.5/±0.25/±0.1 | 180mm | 63mm | 4.75mm | 340g | 15mm | 13mm | 10mm | 0.9V/V | ||||||||||||||
ACT2000C | ±50mm | <±0.5/±0.25/±0.1 | 295mm | 76mm | 4.75mm | 511g | 15mm | 10mm | 14mm | 1.5V/V | ||||||||||||||
ACT3000C | ±75mm | <±0.5/±0.25/±0.1 | 406mm | 114mm | 4.75mm | 653g | 15mm | 24mm | 15mm | 1.5V/V | ||||||||||||||
ACT4000C | ±100mm | <±0.5/±0.25/±0.1 | 452mm | 127mm | 4.75mm | 710g | 15mm | 8mm | 14mm | 3.2V/V | ||||||||||||||
ACT6000C | ±150mm | <±0.5/±0.25 | 643mm | 178mm | 4.75mm | 1.0kg | 15mm | 12mm | 17mm | 2.4V/V | ||||||||||||||
ACT8000C | ±200mm | <±0.5/±0.25 | 833mm | 254mm | 4.75mm | 1.4kg | 32mm | 22mm | 25mm | 1.5V/V | ||||||||||||||
ACT10000C | ±250mm | <±0.5/±0.25 | 1030mm | 305mm | 4.75mm | 1.6kg | 27mm | 34mm | 35mm | 2.0V/V | ||||||||||||||
ACT15000C | ±380mm | <±0.5 | 1435mm | 406mm | 4.75mm | 2.1kg | 19mm | 13mm | 13mm | 3.2V/V | ||||||||||||||
ACT18500C | ±470mm | <±0.5 | 1702mm | 508mm | 6.00mm | 2.5kg | 27mm | 5mm | 33mm | 3.6V/V |
Spring return version. | ||||||||||||||||||||
Our spring displacement transducer has bearings to guide the armature inside the measurement sensor and a spring which pushes the armature to the fully out position. Spring return LVDTs are appropriate where it is not possible to connect the transducer armature to the moving component being measured. | ||||||||||||||||||||
|
||||||||||||||||||||
Type | Range | Linearity error (% F.S.) | L | X (nom) | Total weight | Spring force (nom) | Sensitivity (nom) | |||||||||||||
Spring force at X | Spring rate | Inward over-travel | Outward over-travel | |||||||||||||||||
ACT500A | ±12.5mm | <±0.5/±0.25/±0.1 | 133mm | 38mm | 184g | 1.3N | 0.2N/cm | 1mm | 13mm | 0.7V/V | ||||||||||
ACT1000A | ±25mm | <±0.5/±0.25/±0.1 | 161mm | 63mm | 227g | 2.0N | 0.3N/cm | 3mm | 10mm | 0.9V/V | ||||||||||
ACT2000A | ±50mm | <±0.5/±0.25/±0.1 | 276mm | 75mm | 398g | 1.8N | 0.2N/cm | 8mm | 14mm | 1.5V/V | ||||||||||
ACT3000A | ±75mm | <±0.5/±0.25/±0.1 | 387mm | 114mm | 483g | 6.0N | 0.4N/cm | 15mm | 15mm |
1.5V/V |