美国CIRS CT PMMA 007 DOSE Phantom CT模体

以下为美国CIRS CT PMMA 007 DOSE Phantom CT模体详细参数信息,美国CIRS CT PMMA 007 DOSE Phantom CT模体图片由深圳市湾边贸易有限公司提供,美国CIRS CT PMMA 007 DOSE Phantom CT模体

美国CIRS CT PMMA 007 DOSE Phantom CT模体
最小起订量:1      计量单位:个      产品单价:1.00      供货总量:10

深圳湾边贸易美国CIRS CT PMMA 007 DOSE Phantom CT模体 CIRS CT模体 MODEL 007 007A。

厂家:美国Computerized Imaging Reference Systems, Incorporated (美国CIRS)

 

For all computed tomography systems, the Food and Drug Administration recommends measuring the CT Dose Index (CTDI). Each section of the CIRS CT Dose Phantoms can provide separate dose information.  The user can also measure maximum, minimum and mid-range values of the nominal tomographic section thickness when performing dose profile measurements.

Each phantom consists of a set of nesting 15 cm thick solid PMMA disks measuring 16 cm (head) and 32 cm (body) in diameter.  The adult head disk is also suitable for pediatric body measurements. The Model 007A includes a third nesting disk measuring 10 cm in diameter for pediatric head measurements. Handles on the body and head are provided for ease in handling and maneuverability.

Through holes measuring 1.31 cm in diameter will accommodate standard CT probes. Acrylic rods are provided to plug the holes when not in use. The acrylic rods are machined to receive 1 mm diameter TLD rods.

The Model 007 & 007A are manufactured to comply with the FDA’s performance standard, 21 CFR 1020.33 that details the measurement requirements.

Features:

  • Abdominal, Adult Head, Pediatric Head configurations

  • PMMA disks and plugs with density of 1.10 g/cc

  • 1.31 cm diameter holes sized for standard CT Dose probes

  • Nesting PMMA disks minimize storage space

Compatiblewith all CT scanners

An optional Support Bracket, Model 007-01, can be used to suspend the CT Dose Phantoms above the imaging couch and align it along the axis of X-ray tube rotation.  This enables the phantom to be used to assess CT dose in helical mode or any mode that requires the extended travel of the imaging couch or a wide beam.  This set-up might be used to address the dosimetry approach described in TG111.  An additional application of the support bracket is to provide a body to simulate continous scatter radiation from the patient during helical CT for dose safety measurements inside and outside the exam room. 

 

MODEL 007
 

Overall Dimensions 31.8 cm x 31.8 cm x 15 cm  (12.5" x 12.5" x 5.5")   
 
       
Weight 13 kg  (29 lb)
 
Materials PMMA

Model 007 Includes      (1) Abdominal Cylinder

(1) Adult Head Cylinder

(9) Acrylic Rods

(1) Foam Lined Carry Case












源自:深圳市湾边贸易有限公司